Ransomware attackers specifically target and attempt to destroy backup systems to increase the probability of payment. Hardening your system is critical. Please ensure you have reviewed your platform security using the Security Hardening Checklist
Cohesity

COHESITY Documentation

Explore our documentation to get started, discover products & new features, access troubleshooting guides, register sources, platforms support.

Products
Data Security Alliance
Visit Cohesity.com
Demos
Support
Blogs
Developers
Partner Portals
Cohesity Community
© 2026 Cohesity, Inc. All Rights Reserved.
Terms of Use|
Privacy Policy|
Legal|
  1. Home
  2. NetBackup™ Deduplication Guide
  3. MSDP server evacuation
  4. Managing the MSDP server evacuation using the command-line
  5. Resuming the MSDP server evacuation using the command-line
NetBackup™ Deduplication Guide

Resuming the MSDP server evacuation using the command-line

To resume the MSDP server evacuation using the command-line

  1. Update the existing evacuation configuration file or create a new configuration file in the following format:
    V7.5 "operation" "update-virtual-volume" string
    V7.5 "virtualVolume" "<mvg-volume>" string
    V7.5 "diskVolume" "<msdp-server1>:<msdp-volume1>:Y" string
    V7.5 "diskVolume" "<msdp-server2>:<msdp-volume2>:Y" string
    V7.5 "diskVolume" "<msdp-server...>:<msdp-volume...>:Y" string
    

    Use :ES instead of :Y as the suffix for the MSDP server and disk volume, which is in evacuation mode.

    For example:

    cat /root/evacuate-host4.cfg
    V7.5 "operation" "update-virtual-volume" string
    V7.5 "virtualVolume" "mvg-local" string
    V7.5 "diskVolume" "mvgdemo-host2.mvgdemo.com:PureDiskVolume:Y" string
    V7.5 "diskVolume" "mvgdemo-host3.mvgdemo.com:PureDiskVolume:Y" string
    V7.5 "diskVolume" "mvgdemo-host4.mvgdemo.com:PureDiskVolume:ES" string
    
  2. Apply the configuration to resume.

    nbdevconfig -setconfig -storage_server <mvg-server> -stype PureDisk -configlist <configuration-file>