  3. Section III. Certified configurations
  4. Capacity Manager configurations
  5. Array/LUN performance Data Collection

Array/LUN performance Data Collection

The following array families are supported for block storage LUN performance and port performance data collection.

See Array/LUN performance notes.

Table: Array Family

Array Family

Rd/Wrte IO/sec

Total IO/sec

Rd/WrteMB / sec

Rd/Wrte Cache Hits/sec

Rd/Wrte Respond(ms)

Total Respond(ms)

Dell Compellent

X

X

X

X

--

--

EMC VNX

X

Calc.

X

X

X

Calc.

EMC Symmetrix

X

X

X

X

--

--

EMC XtremIO

Calc.

Calc.

Calc.

--

X

X

HDS Tuning Manager

X

Calc.

X

X

X

X

HP 3PAR

X

X

X

X

X

X

IBM SVC

X

X

X

--

--

--

IBM XIV

X

X

X

X

X

X

NetApp ONTAP 7-Mode (Block only)

X

Calc.

X

--

--

Avg Latency

Pure Storage FlashArray

X

Calc.

X

--

X

Calc.

Array/LUN performance notes

The following notes apply to array families are supported for block storage LUN performance and port performance data collection.

Table: Array families supporting block storage LUN performance and port performance data collection.

Array Family

Notes

EMC VNX

The minimum FLARE OS version required to capture response times is 04.30.000.5.524 A11. Note that VNX (Block) will have completely different FLARE releases and all support the collection of the counter fields needed for capturing response time, starting with FLARE version 05.31.000.5.006 A01. Enable statistics logging on the VNX system.

EMC XtremIO

For EMC XtremIO, the values obtained are averages over the time interval. The Read/Write/Total IOs and the Read/Write MBs are multiplied by the time interval and persisted.

HDS Tuning Manager

For Hitachi arrays: To collect performance data from Hitachi Tuning Manager, the Data Collector must be installed on the same server as Tuning Manager. And, a single Data Collector policy must be used to collect both the capacity data from the Device Manager server and the performance data from the Tuning Manager server.

NetApp ONTAP 7-Mode (Block only)